Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.76.2012.tde-11102012-163617
Document
Auteur
Nom complet
Jaciara Cássia de Carvalho Santos
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2012
Directeur
Jury
Zucolotto, Valtencir (Président)
Souza, Flavio Leandro de
Wohnrath, Karen
Titre en portugais
Imobilização da enzima glicose oxidase em filmes nanoestruturados para aplicação em biossensores
Mots-clés en portugais
Biossensores
Glicose
Imobilização
Nanopartículas de ouro
Técnica de Automontagem
Resumé en portugais
Aplicações de nanomateriais em biossensores têm recebido muito interesse nos últimos anos. Entre os vários tipos de biossensores estudados, sensores de glicose têm recebido destaque devido a sua importância em diagnósticos clínicos. Apesar do grande avanço no monitoramento de glicose nas últimas décadas, ainda há muitos desafios para alcançar um monitoramento de glicemia continuo, clinicamente preciso, em conexão a um sistema fechado otimizado para a entrega de insulina no corpo. Esta dissertação descreve a fabricação de filmes layer-by-layer (LbL) obtidos a partir da enzima glicose oxidase (GOx) e dos polieletrólitos poli(amidoamina) de geração 4 (PG4) e o hibrido PG4 com as nanopartículas de ouro (PG4AuNp). As nanopartículas de ouro foram sintetizadas em meio aquoso usando o dendrímero PG4, o ácido cloroáurico (HAuCl₄4) e ácido fórmico. As medidas de espectroscopia UV-Vis dos filmes automontados em substratos de quartzo mostraram um crescimento linear em função do número de bicamadas depositados apenas para o filme PG4-GOx. No filme PG4AuNp-GOx o crescimento não é linear. Em adição às caracterizações ópticas, estrutural e eletroquímica, os filmes LbL, depositados sobre substratos de vidro recoberto com óxido de índio (ITO) foram testados para a atuação em biossensores de peróxido de hidrogênio e de glicose. A biofuncionalidade da GOx e a viabilidade do método como biossensor foi demonstrada pelo aumento da corrente em função das sucessivas adições de alíquotas de glicose à solução. Os filmes sem nanopartículas não foram sensíveis a glicose. O biossensor com melhor desempenho foi o ITO-(PG4AuNp-GOx) com 5 bicamadas, que mostrou-se linear na faixa de 0 a 4,8 mM de glicose com sensibilidade 0,013 μA/mM e limite de detecção 0,44 mmolL ¹.
Titre en anglais
Glucose oxidase immobilization on nanostructured thin films for application in biosensors
Mots-clés en anglais
Biosensors
Glucose
Gold Nanoparticles
Immobilization
Self-assemble technique
Resumé en anglais
Applications of nanomaterials for biosensors have been target of substantial research in the last years. Among a large number of biosensors, glucose biosensors have attracted attention due to their applications in clinical diagnostics. Despite the remarkable progress in glucose biosensors in the last decades, there are still many challenges in achieving clinically accurate continuous glycemic monitoring in connection to closed-loop systems aimed at optimal insulin delivery. This dissertation describes the fabrication of layer-by-layer (LbL) films obtained from the enzyme glucose oxidase (GOx) and the polyelectrolytes poli(amidoamine) generation 4 (PG4) and PG4 containing gold nanoparticles (PG4AuNp). Gold nanoparticles were synthesized in aqueous solution using formic acid, PG4 and HAuCl ₄. UV-vis spectroscopy showed a linear growth on quartz substrate only in the system PG4-GOx. In addition to the optical, structural and electrochemistry investigation, these LbL films deposited on ITO-coated glass were employed as electrochemical glucose biosensors. The biofunctionality of GOx and feasibility of the method as biosensor are demonstrated by the increase of reduction current upon additions of successive aliquots of glucose. The biosensor ITO-(PG4AuNp-GOx) ₅ with the optimum performance had a detection limit of 0.44 mmolL¹ with a linear response in the range from 0 to 4.8 mmolL¹ and sensibility 0.013μA/mmolL ¹.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-10-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.