Disertación de Maestría
DOI
https://doi.org/10.11606/D.82.2017.tde-03102017-162557
Documento
Autor
Nombre completo
Ana Carolina Trevisan
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2015
Director
Tribunal
Ana, Lauro Wichert (Presidente)
Moraes, Éder Rezende
Tumas, Vitor
Título en portugués
Avaliação de diferentes métodos de reconstrução de imagens no processamento de SPECT cerebral com simulador antropomórfico estriatal
Palabras clave en portugués
Doença de Parkinson
Filtros
Reconstrução de imagens
SPECT cerebral
Resumen en portugués
A dopamina (DA) é um neurotransmissor sintetizado nos neurônios dopaminérgicos da substância nigra, possuindo efeito importante sobre o Sistema Nervoso Central (SNC), dentre as quais a sensação de prazer e a motivação. Uma alteração nos transportadores de dopamina (DATs) se caracteriza por uma desordem progressiva do movimento devido à disfunção dos neurônios secretores de dopamina, gerando a Doença de Parkinson (DP). Por ser um distúrbio mais comum entre um espectro de doenças neurológicas, é necessário um estudo mais aprofundado para melhor diagnóstico. Esta dissertação apresenta um estudo do desempenho do filtro butterworth passa-baixa na reconstrução analítica Filtered Backprojection - FBP e reconstrução iterativa Ordered Subsets Expectation Maximization - OSEM, para garantir a qualidade da imagem de SPECT cerebral, adquirida pelo fantoma antropomórfico estriatal. Por avaliação interindividual de quatro especialistas em medicina nuclear, foram aplicadas notas para a análise visual das imagens, garantindo a qualidade da resolução espacial, contraste, ruído e diferenciação anatômica do corpo estriado. Para cada tipo de reconstrução, houve 49 imagens do corpo estriado, variando os valores das covariáveis apresentadas pelos algoritmos (iteração, subsets, ordem e frequência de corte). A fim de resultados consistentes, foram utilizados a regressão linear e o teste T-Student pareado. Os dados coletados demonstraram que é necessário utilizar um intervalo confiável de frequência de corte para FBP (0,9 a 1,6) e para OSEM (1,2 a 1,5) e variar a ordem de 0 a 10 que não influenciará a imagem. Para a reconstrução OSEM, ficou comprovado que o valor de iteração (i) e o número de subsets (s) que garantem melhor qualidade foram os mesmos que a empresa do algoritmo utilizado sugeriu (3i 8s). Esta, também, mostrou evidências de melhor qualidade da imagem, quando comparada à reconstrução FBP. Para uma imagem de qualidade, representando uma reconstrução confiável e uma análise visual segura, é necessário utilizar o intervalo de valores encontrados das covariáveis ordem e frequência de corte do filtro butterworth passa-baixa na reconstrução FBP e OSEM. Também é necessário utilizar o valor de iteração e subsets que a empresa sugeriu, e a reconstrução OSEM mostrou superioridade nas imagens comparadas à FBP, mas se o serviço não utilizar ainda este tipo de algoritmo, a imagem com FBP no intervalo proposto também garantirá a qualidade.
Título en inglés
Evaluation of different methods of image reconstruction in brain SPECT processing with striatal anthropomorphic simulator
Palabras clave en inglés
Brain SPECT
Filters
Image reconstruction
Parkinson's disease
Resumen en inglés
Dopamine is a synthesized neurotransmitter in dopaminergic neurons of the substantia nigra where it has an important effect on the central nervous system (CNS), such as the feeling of pleasure and motivation. A change in the dopamine transporters (DATs) is characterized by a progressive disorder of movement due to a dysfunction of the dopamine secreting neurons, causing Parkinson's Disease (PD). As it is a more common disorder among a spectrum of neurological diseases, further studies are necessary for a better diagnosis. This study presents an investigation on the performance of the low-pass butterworth filter in the Filtered Backprojection analytic reconstruction - FBP and Ordered Subsets Expectation Maximization iterative reconstruction - OSEM to ensure the quality of brain SPECT image, acquired by the anthropomorphic striatal phantom. By individual evaluation of four nuclear medicine specialists, grades were applied to the visual analysis of the images, ensuring the quality of the spatial resolution, contrast, noise and anatomical differentiation striatum. For each type of reconstruction, there were 49 pictures of the striatum, varying the values of covariates submitted by the algorithms (iteration, subsets, order and cutoff frequency). In order to obtain consistent results, we used linear regression and T-Student paired test. The collected data showed that it is necessary to use a reliable interval of cutoff frequency for both the FBP (0.9 to 1.6), and OSEM (1.2 to 1.5), and varying the order of 0 to 10, which does not influence the image. For OSEM reconstruction, it has been verified that the iteration value (i) and the number of subsets (s) ensuring best quality was the same as the company's algorithm suggested (3i 8s). This also showed evidence of better image quality when compared to FBP reconstruction. For an image quality, representing a reliable reconstruction and a safe visual analysis, you must use the range of values found of covariates order and cutoff frequency of the butterworth low-pass filter on the FBP and OSEM reconstruction. You must also use the iteration value and subsets that the company suggested and the OSEM reconstruction showed superiority on the images compared to FBP, but if the service does not use this type of algorithm, the image with FBP in the proposed range, also ensures quality.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-10-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.