• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.82.2004.tde-03122004-124215
Documento
Autor
Nombre completo
Jesulino Bispo dos Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2004
Director
Tribunal
Silva, Orivaldo Lopes da (Presidente)
Castro Neto, Jarbas Caiado de
Pereira, Jose Carlos
Título en portugués
Sensor de frente de onda para uso oftalmológico
Palabras clave en portugués
aberroscópio
engenharia biomédica
frente de onda
instrumentação médica
instrumentação oftalmológica
óptica aplicada
sensor de fase
sensor Hartmann-Shack
Resumen en portugués
Este trabalho descreve os passos envolvidos no desenvolvimento de um protótipo de aberroscópio para uso oftalmológico. Este instrumento faz incidir no fundo do olho humano um feixe luminoso de baixa potência e amostra, por meio do método de Hartmann, as frentes de onda da luz espalhada. A partir dos dados coletados, a forma das frentes de onda são reconstituídas e as aberrações eventualmente existentes no olho são calculadas e representadas por intermédio dos polinômios de Zernike. Aqui são expostos os fundamentos deste método, algumas das suas propriedades e limitações. Também é mostrada a caracterização funcional do protótipo desenvolvido, testando-o com elementos ópticos de propriedades conhecidas
Título en inglés
Wavefront sensor for ophthalmological use
Palabras clave en inglés
aberroscope
applied optics
biomedical engineering
Hartmann-Shack sensor
medical instrumentation
ophthalmological instrumentation
phase sensor
wavefront
Resumen en inglés
This work describes the steps involved in the aberroscope prototype development for ophthalmological use. This instrument injects inside the human eye a low power light beam and sample, by Hartmann method, the wavefronts produced by ocular fundus light scattering. From collected data, the wavefront shape is reconstructed and the eye aberrations that eventually existent are calculated and adjusted by Zernike polynomials. Are discussed the method foundations, some of properties and limitations. Also the functional characterization of the developed prototype is shown, by testing it with optical elements of known properties
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
JBS_Dissertacao.pdf (28.05 Mbytes)
Fecha de Publicación
2005-06-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.