• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.82.2017.tde-24102017-122542
Documento
Autor
Nombre completo
Renato Alves Cazon
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 1999
Director
Tribunal
Volpon, José Batista (Presidente)
Louzada, Mário Jefferson Quirino
Paulin, José Baptista Portugal
Título en portugués
Ensaio mecânico de compressão axial e flexão em três pontos em complexo tíbio-fibular de ratos adultos jovens
Palabras clave en portugués
Biomecânica
Ensaio mecânico
Rato
Tíbio-fibular
Resumen en portugués
Este estudo teve como objetivo investigar uma provável função mecânica da fíbula no complexo tíbio-fibular de ratos. Para tanto, os complexos tíbio-fibulares de 20 ratos da raça Norvegicus Albinus, variedade Wistar, foram submetidos a esforços de compressão axial e flexão em três pontos. Os animais eram adultos jovens, todos machos com peso corporal médio de 350 g. Foram utilizados 20 pares de tíbias para cada ensaio, sendo que, de um dos lados de cada par, a fíbula foi mantida e, do outro lado, removida. Foi utilizado uma máquina universal de ensaio para a realização de ambos os ensaios mecânicos. Os valores foram obtidos na forma de carga versus deformação (ensaio de compressão), e carga versus deflexão (ensaio de flexão). Os seguintes parâmetros foram analisados: carga máxima, deformação máxima e rigidez. Da análise dos resultados foi concluído que a fíbula, no rato, não aumenta a resistência do complexo tíbio-fibular. Assim, a presença da fíbula parece estar mais relacionada com função de inserções musculares do que fortalecimento tíbio-fibular.
Título en inglés
Mechanical testing in compression and three point flexion of the rat tibiofibular complex
Palabras clave en inglés
Biomechanics
Mechanical test
Rat
Tibiofibular complex
Resumen en inglés
This study was conducted to investigate the contribution of the fibula to the mechanical resistance of the tibiofibular complex in the rat (both banes are fused distally). Twenty adult wistar rats were used as donor animals of twenty paired tibias. For each pair of bones in one side the fibula was excited and in the other side it was maintained. In a test machine the mechanical tests were done in three flexion and axial compression. The results were plotted either in load x deformation or load x deflection graphs the following parameters were analysed: ultimate load, ultimate deformation and rigidity. It was concluded that the fibula does not increase the mechanical strength of the tibiofibular complex, but it may play a role as an anchorage for the muscles that act on the foot.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-10-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.