• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.82.2006.tde-30072007-163145
Documento
Autor
Nombre completo
Mauricio Bordini do Amaral
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2006
Director
Tribunal
Plepis, Ana Maria de Guzzi (Presidente)
Garcia, Sérgio Britto
Oliveira, Rodrigo Cardoso de
Título en portugués
Citotoxidade in vitro e biocompatibilidade in vivo de compósitos a base de hidroxiapatita, colágeno e quitosana
Palabras clave en portugués
Biocompatibilidade in vivo
Citotoxicidade in vitro
Colágeno
Hidroxiapatita
Quitosana
Resumen en portugués
Na engenharia de tecidos os biomateriais são usados tanto para induzir a formação óssea no tecido adjacente quanto agir como matriz temporária de células e outros agentes. Compósitos biodegradáveis a base de hidroxiapatita, colágeno e quitosana foram preparados como arcabouços para permitir a regeneração óssea. Este estudo teve como objetivo avaliar a toxicidade celular in vitro de novos compósitos de substituição óssea e o seu comportamento biológico após implantação subcutânea no processo de remodelação e cicatrização tecidual. Foram confeccionadas mantas a base de hidroxiapatita (HA), obtida por desproteinização e calcinação do osso bovino, colágeno (Col), obtido por tratamento alcalino do tendão bovino e quitosana (Qui), extraída do gládio de lula, nas seguintes proporções: B1) HA (mistura de partículas <0,2 mm e entre 0,2 e 1,18 mm, proporção 1:1) + Blenda (Col 1% + Qui 0,5%, proporção 1:1), proporção HA:Blenda 1:5; B2) HA (mistura de partículas <0,2 mm e entre 0,2 e 1,18 mm, na proporção 1:1) + Col 1%, proporção HA:Col 1:5; B3) HA (partículas <0,2 mm) + Col 1%, na proporção 1:5. O teste de citotoxicidade in vitro foi realizado pelo método de difusão de extrato em solução (brometo de tetrazolio - MTT). Os biomateriais descritos acima foram avaliados juntamente com o controle positivo (látex), sendo que todos foram submetidos a procedimentos de extração de acordo as normas da ISO10993-5. O meio de cultura foi utilizado como controle negativo. Foram utilizadas duas linhagens celulares: células tumorais de laringe humana HEp (ATCC-CCL-23) e células normais de rim de macaco verde africano (Cercopithecus aethiops) VERO (n=3). A citotoxicidade foi avaliada em um espectrofotômetro (absorbância de 570nm). No teste de biocompatibilidade as amostras foram implantadas no subcutâneo da região dorsal de 51 ratos Wistar. Histomorfometria de espessura e qualidade da cápsula fibrosa, interface implante-tecido, infiltrado inflamatório e crescimento celular interno foram realizados aos 3, 7 e 28 dias após cirurgia (n=5). Imunohistoquímica foi realizada para caracterizações adicionais do infiltrado de macrófagos. No teste de citotoxicidade as linhagens celulares mostraram resultados semelhantes. Não houve diferença entre os compósitos e o controle negativo. Foi demonstrado que os compósitos avaliados não apresentaram efeitos tóxicos em comparação ao controle positivo. No teste subcutâneo a qualidade e a espessura da cápsula não apresentaram diferenças significantes entre os biomateriais e os períodos de implantação. A resposta celular inflamatória aos 7 dias foi mais intensa no biomaterial B1, seguido pelo biomaterial B2 e B3. Uma baixa reação de corpo estranho foi observada em todos os biomateriais, caracterizada pela presença de poucos macrófagos. Ocorreu um intenso crescimento celular no interior do biomaterial B3 aos 28 dias. A análise histológica sugere que esses biomateriais são bem tolerados com baixa reação tecidual inflamatória. Concluímos que os três biomateriais avaliados não apresentaram evidências de citotoxicidade in vitro e, in vivo, mostraram uma boa biocompatibilidade. Esses materiais mostraram-se bons candidatos a matrizes para engenharia de tecidos e enxertos para regeneração óssea.
Título en inglés
In vitro cytotoxicity and subcutaneous biocompatibility evaluation of hydroxyapatite / collagen / chitosan composites
Palabras clave en inglés
Chitosan
Collagen
Hydroxyapatite
In vitro cytotoxicity
Subcutaneous implant test
Resumen en inglés
The biodegradable hydroxyapatite / chitosan / collagen composites of similar composition of the normal human bone were prepared as a biomimetic scaffold for bone replacement and regeneration. The aim of the present study was to evaluate the in vitro cytotoxicity of three new bone grafts and the influence of these synthetic grafts on the inflammatory response and remodeling of connective tissue during wound-healing process. Three biomaterials were developed: B1 = hydroxyapatite (particles size <0,2 mm + between 0,2 and 1,18 mm) / collagen 1% / chitosan 0.5%; B2 = hydroxyapatite (particles size <0,2 mm + between 0,2 and 1,18 mm) / collagen 1% and B3 = hydroxyapatite (particles size <0,2 mm) / collagen 1%. These biomaterials were investigated using a tetrazolium-based calorimetric assay (MTT assay). Latex was used as positive control and the culture medium as a negative control. Two cell lines were used to evaluate the effect of cell type on the toxicity results: human tumor cells HEp-2 (ATCC-CCL23) and monkey normal cells (VERO). Extracts from the biomaterials were obtained according to ISO 10993-12 standards. The cytotoxicity was assessed in a spectrophotometer (the absorbance was read at 570 nm). There were two independent experiments in triplicates. All values were expressed as mean values '+ OU -' standard deviation. In the biocompatibility test the samples were implanted subcutaneously in the dorsal lumbar region of 51 Wistar rats. Histomorphometric evaluation of capsule thickness, capsule quality, implant-tissue interface, infiltrate / inflammation and cellular growth within implant was performed 3, 7 and 28 days post-operatively (n=5). Immunohistochemistry was performed for further characterization of the macrophages infiltrate. In cytotoxicity test the cell lines showed similar results. There is no difference in values between the composites and negative control. The values of composites were significant different than the positive control. It was showed that none of the tested composites presents toxic effects for the cell lines evaluated in comparison with positive control. In the subcutaneous test the capsule thickness and capsule quality didn't show significant differences between the biomaterials and time of implantation. The biomaterial B1 showed significant difference in inflammatory cellular response than B2 and B3 at 7 days. A low ongoing foreign body reaction was observed in all biomaterials characterized by infiltration of few macrophages. A significant cellular growth within the B3 was observed at 28 days. Histological analysis suggested that the biomaterials were well tolerated with low inflammatory response. According to this study, the three bone grafts evaluated showed no evidence of cytotoxicity and good biocompatibility which makes them suitable candidates to design of bone replacement graft material.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-07-31
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.