• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.82.2008.tde-31082010-170913
Document
Auteur
Nom complet
Daiane Müller de Bem
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2008
Directeur
Jury
Parizotto, Nivaldo Antonio (Président)
Duarte, Ana Cláudia Garcia de Oliveira
Silva, Orivaldo Lopes da
Titre en portugais
Análise histológica em tecido epitelial sadio de ratos Wistar (in vivo) irradiados com diferentes intensidades do ultra-som
Mots-clés en portugais
Dosimetria
Lesão do tecido biológico
Ultra-som terapêutico
Resumé en portugais
A energia ultra-sônica é um dos recursos físicos amplamente utilizado e pesquisado nos tratamentos de fisioterapia e diagnósticos médicos. Sabe-se que diante de uma escassa literatura dos efeitos do ultra-som em tecidos sadios, muitos profissionais fisioterapeutas acabam realizando aplicações infundadas de métodos e parâmetros. O objetivo desta pesquisa foi avaliar possíveis alterações do tecido sadio in vivo de ratos Wistar irradiados com diferentes intensidades, analisando a histologia e morfometria. Foram utilizados 30 ratos da linhagem Wistar, distribuídos aleatoriamente em 5 grupos de 6 animais cada. Foi escolhida a região dorsal do lado direito para tratamento com área de 4 'CM POT.2'. O lado esquerdo serviu como controle em todos os grupos. O tratamento foi feito durante 4 dias com 2 minutos de irradiação. Para verificar a intensidade de saída, utilizou-se o dosímetro de precisão antes da aplicação do ultra-som em cada animal. Foi realizada uma análise histológica descritiva e morfometria por meio do software Image Tool. Como resultado pode-se observar um discreto infiltrado inflamatório e adelgaçamento das fibras da derme, principalmente dos grupos irradiados com 1.5 e 2 W/'CM POT.2'. Notou-se também um aumento na espessura da epiderme nas amostras dos animais irradiados quando comparado com o controle. Para avaliar os resultados quantitativos, utilizou-se como análise estatística ANOVA "one way" e o teste "pos hoc" de Tukey com nível de significância p < 0,01. Em 120 medidas da espessura da epiderme obtiveram-se diferenças significativas do grupo controle com os grupos irradiados com (1.0, 1.5 e 2.0 W/'CM POT.2'). Concluímos diante dos resultados que houve alterações no tecido sob ação do US nas doses maiores, o que nos alerta para possíveis implicações do uso do US em estética.
Titre en anglais
Histological analyses in healthy epithelium tissue irradiated with different ultrasound intensities in Wistar rats in vivo
Mots-clés en anglais
Dosimetry
Side effects
Therapeutic ultrasound
Tissue damage
Resumé en anglais
The ultrasound (US) energy is one of the resources widely used and researched in both physio-therapist treatment and in medical diagnosis. In front of a scarce literature about the US effects in healthy tissues, many professionals have carried out unfounded applications of methods and parameters. So, the aim of this research was evaluate, through the histology, possible alternations in healthy tissues of Wistar rats in vivo irradiated with different intensity, analyzing the qualitative and quantitative histological slides. We used 30 Wistar rats randomly distributed in 5 groups of animals each. The local chosen for receiving the treatment was the dorsal right side, whose area was 4 'CM POT.2'. The left side was used as control of the animal itself for all the groups. The rats underwent the treatment during 4 days exposed to 2 minutes of irradiation. In order to check the energy output, the precision dosimeter was used before US application in each animal. The histological slides were evaluated qualitatively in the microscope and quantitatively through the image tool software. The qualitative result shows a discrete inflammatory process with infiltration and atrophy dermis fibers, mainly in the groups with higher US dosage. In the quantitative aspect, we found epidermis thickness increased in the 1.5 and 2 W/'CM POT.2' of US, with statistical difference (ANOVA) compared to control. We conclude that US therapy can be dangerous with high dosage applied in the intact skin.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-09-02
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.