Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2013.tde-04072013-134929
Documento
Autor
Nombre completo
Flavio William Lacerda
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Koskinas, Marina Fallone (Presidente)
Medeiros, José Agostinho Gonçalves de
Takeda, Mauro Noriaki
Título en portugués
Padronização de Ga-68 em sistema de coincidências 4πβ-γ
Palabras clave en portugués
68Ga
Coincidência por Software
Monte Carlo
padronização
PET
pósitrons
Resumen en portugués
O presente trabalho tem como objetivo a padronização de 68Ga, um emissor de pósitrons de meia-vida curta, usado em PET (Tomografia por Emissão de Pósitrons). A padronização do 68Ga foi realizada em um sistema de coincidência 4πβ-γ, que consiste de um detector proporcional em geometria 4π a gás fluente acoplado a um detector de cristal semicondutor HPGe, para a detecção de raios gama. A aquisição de dados foi realizada por meio de um Sistema de Coincidência por Software (SCS), desenvolvido no Laboratório de Metrologia Nuclear (Laboratório de Metrologia Nuclear - LMN) no IPEN-CNEN / SP. Os resultados finais foram obtidos a partir de um ajuste de curva multiparamétrica aplicando-se uma metodologia que leva em consideração a matriz de covariância combinando os resultados experimentais com aqueles determinados pela simulação Monte Carlo.
Título en inglés
68Ga standardization by means of a 4πβ-γ coincidence system
Palabras clave en inglés
68Ga
Coincidence for Software
Monte Carlo
SCTAC
standardization
Resumen en inglés
The present work aims the standardization of 68Ga, a positron emitter of short half-life used in PET (Positron Emission Tomography). The 68Ga standardization was performed in a 4πβ-γ coincidence system that consists of a gas-flow proportional counter (PC) in 4π geometry coupled to a HPGe crystal, for gamma-ray detection. The data acquisition was carried out by means of a Software Coincidence System (SCS) developed at the Nuclear Metrology Laboratory (Laboratório de Metrologia Nuclear LMN) at the IPEN-CNEN/SP. The final results were obtained from a multiple curve fitting applying a covariance matrix methodology combining experimental results with those determined by the Monte Carlo simulation.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-07-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.