Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2006.tde-08012007-195253
Documento
Autor
Nombre completo
Rosiane Aparecida da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2005
Director
Tribunal
Rodrigues, Laura Natal (Presidente)
Cruz, José Carlos da
Todo, Alberto Saburo
Título en portugués
"Dosimetria de filtros dinâmicos aprimorados IPEN/CNEN-SP"
Palabras clave en portugués
dosimetria
filtros dinâmicos aprimorados
Resumen en portugués
O objetivo deste trabalho foi realizar a dosimetria de filtros dinâmicos aprimorados (“Enhanced Dynamic Wedge" – EDW). Isso foi feito com dois intuitos: 1) a avaliação da implementação clínica do filtro dinâmico aprimorado considerando-se suas vantagens e desvantagens; e 2) a comparação entre a eficiência e a melhor aplicabilidade de três sistemas dosimétricos diferentes em conjunto com o filtro dinâmico aprimorado. Os sistemas dosimétricos utilizados foram: o Sistema de Imagem de Feixe (“Beam Image System" – BIS2G), da Scanditronix-Wellhöfer, uma câmara de ionização cilíndrica de 0,6 cm3 do tipo Farmer, e um arranjo linear de câmaras de ionização múltiplas (“Ionization Chamber Linear Detector Array") com 23 câmaras de ionização cilíndricas de 0,14 cm3, tipo Farmer. Com o Sistema de Imagem de Feixe – BIS2G foi possível obter curvas de fluência que permitiram analisar a simetria dos perfis de fluência, linearidade da dose, efeito da taxa de dose e efeito da gravidade, características diretamente ligadas à qualidade do funcionamento do filtro dinâmico aprimorado, além de ter sido possível também calcular o fator filtro para campos simétricos. Com a câmara de ionização mediu-se a porcentagem de dose em profundidade - PDP e calculou-se o fator filtro para campos simétricos e campos assimétricos (uma das vantagens do EDW). Com o arranjo linear de câmaras de ionização múltiplas foi possível obter curvas de isodose que permitiram a verificação da simetria e a comparação com os resultados obtidos com o BIS2G, além do cálculo do fator filtro para campos simétricos. O fator filtro calculado através de medidas tomadas com os três sistemas foi também comparado com resultados obtidos por dois formalismos, de Gibbons1 e de Klein et al 2, bem conhecidos da literatura e que serviram para a validação dos resultados e deste trabalho. Destas comparações verificou-se que os ângulos do filtro dinâmico aprimorado que apresentam maior diferença entre resultados obtidos e os formalismos foram os ângulos de 45º e de 60º em relação ao método de Klein et al que apresentaram diferenças de 2,1% em relação ao BIS2G, 1,9% em relação à câmara de ionização e 1,1% em relação ao arranjo linear de câmaras de ionização.
Título en inglés
Enhanced Dynamic Wedges Dosimetry
Palabras clave en inglés
dosimetry
enhanced dynamic wedges
Resumen en inglés
The purpose of this work was to accomplish the dosimetry of Enhanced Dynamic Wedge (EDW). It was carried out with two intents: 1) the evaluation of the clinical implementation of the EDW considering its advantages and disadvantages, and 2) the comparison among the efficiency and the better applicability of three different dosimetric systems in a set with the EDW. The dosimetric systems used were: the Beam Image System (BIS2G), from Scanditronix-Wellhöfer, a cylindrical ionization chamber of 0.6 cm3, type Farmer, and an ionization chamber linear detector array, composed by 23 cylindrical ionization chamber of 0.14 cm3, type Farmer. With the BIS2G was possible to plot graphs of fluence that allowed to analyze the symmetry of the graphs of fluence, linearity of the dose, dose rate effect, and gravity effect, features directly connected to the quality of the working of the EDW, further on having been possible to calculate the wedge factor for symmetric fields. With the ionization chamber it was measured the PDP and it was calculated the wedge factor for symmetric and asymmetric fields (one advantage of EDW). With the array it was possible to plot graphs of isodosis that allowed the checking of the symmetry and the comparison with the results obtained with the BIS2G, besides the calculation of the wedge factor for symmetric fields. The wedge factors obtained from the measurements of the three systems were also compared with the results of the formalisms, of Gibbons1 and of Klein et al 2, both well known if the literature, and that were used to validate the results and the work. From these comparisons was verified that the angles of the EDW that show more difference between the results and the formalisms were the 46º and 60º angles related to the method of Klein et al, which show differences of 2.12% related to BIS2G, 1.92% related to the ionization chamber, and 1.10% related to ionization chamber linear detector array.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-06-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.