Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.85.2005.tde-11052006-163022
Documento
Autor
Nome completo
Fabio de Camargo
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2005
Orientador
Banca examinadora
Tobias, Carmen Cecília Bueno (Presidente)
Jesus, Edgar Francisco Oliveira de
Martins, Marcos Nogueira
Título em português
"Fatores que influenciam a resolução em energia na espectrometria de partículas alfa com diodos de Si"
Palavras-chave em português
detecção de partículas alfa
detector de silício
diodos de Si resistentes a danos de radiação
espectrometria alfa
picos satélites
Resumo em português
Neste trabalho são apresentados os estudos das condições de resposta de um diodo de Si, com estrutura de múltiplos anéis de guarda, na detecção e espectrometria de partículas alfa. Este diodo foi fabricado por meio do processo de implantação iônica (Al/p+/n/n+/Al) em um substrato de Si do tipo n com resistividade de 3 kohm•cm, 300 mícrons de espessura e área útil de 4 mm2. Para usar este diodo como detector, a face n+ deste dispositivo foi polarizada reversamente, o primeiro anel de guarda aterrado e os sinais elétricos extraídos da face p+. Estes sinais eram enviados diretamente a um pré-amplificador desenvolvido em nosso laboratório, baseado no emprego do circuito híbrido A250 da Amptek, seguido da eletrônica nuclear convencional. Os resultados obtidos com este sistema na detecção direta de partículas alfa do Am-241evidenciaram excelente estabilidade de resposta com uma elevada eficiência de detecção (= 100 %). O desempenho deste diodo na espectrometria de partículas alfa foi estudado priorizando-se a influência da tensão de polarização, do ruído eletrônico, da temperatura e da distância fonte-detector na resolução em energia. Os resultados mostraram que a maior contribuição para a deterioração deste parâmetro é devida à espessura da camada morta do diodo (1 mícron). No entanto, mesmo em temperatura ambiente, a resolução medida (FWHM = 18,8 keV) para as partículas alfa de 5485,6 keV (Am-241) é comparável àquelas obtidas com detectores convencionais de barreira de superfície freqüentemente utilizados em espectrometria destas partículas.
Título em inglês
"Factors affecting the energy resolution in alpha particle spectrometry with silicon diodes"
Palavras-chave em inglês
alpha particle detector
alpha spectrometry
hard rad silicon detector
satellite peaks
silicon detector
Resumo em inglês
In this work are presented the studies about the response of a multi-structure guard rings silicon diode for detection and spectrometry of alpha particles. This ion-implanted diode (Al/p+/n/n+/Al) was processed out of 300 micrometers thick, n type substrate with a resistivity of 3 kohm•cm and an active area of 4 mm2. In order to use this diode as a detector, the bias voltage was applied on the n+ side, the first guard ring was grounded and the electrical signals were readout from the p+ side. These signals were directly sent to a tailor made preamplifier, based on the hybrid circuit A250 (Amptek), followed by a conventional nuclear electronic. The results obtained with this system for the direct detection of alpha particles from Am-241 showed an excellent response stability with a high detection efficiency (= 100 %). The performance of this diode for alpha particle spectrometry was studied and it was prioritized the influence of the polarization voltage, the electronic noise, the temperature and the source-diode distance on the energy resolution. The results showed that the major contribution for the deterioration of this parameter is due to the diode dead layer thickness (1 micrometer). However, even at room temperature, the energy resolution (FWHM = 18.8 keV) measured for the 5485.6 MeV alpha particles (Am-241) is comparable to those obtained with ordinary silicon barrier detectors frequently used for these particles spectrometry.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2006-09-26
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI