• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.85.2015.tde-23102015-094126
Documento
Autor
Nombre completo
Osvaldo Luiz da Costa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Rostelato, Maria Elisa Chuery Martins (Presidente)
Araki, Koiti
Sene, Frank Ferrer
Sumiya, Luiz Carlos do Amaral
Zeituni, Carlos Alberto
Título en portugués
Estudo e desenvolvimento de uma nova metodologia de produção de iodo-125 a partir de xenônio-124 pelo método de ativação neutrônica
Palabras clave en portugués
braquiterapia
iodo-125
iodo-126
produção
xenônio-124
Resumen en portugués
Neste trabalho foi desenvolvida uma nova metodologia de produção de iodo-125, que resultou na primeira produção deste radionuclídeo no Brasil. Cápsulas de alumínio foram projetadas, fabricadas e avaliadas para que suportassem condições de pressão, temperatura e fluxo de nêutrons no reator nuclear IEA-R1 do IPEN sem a ocorrência de liberação de material radioativo. Foram projetados, desenvolvidos e fabricados sistemas de carregamento, descarregamento e recuperação dos gases para a manipulação do gás xenônio e do iodo. Foi desenvolvido um novo método de lavagem da cápsula, para dissolução do iodo-125 adsorvido nas paredes, por meio de imersão em banho ultrassônico. Foram irradiadas três cápsulas no reator nuclear IEA-R1, por um período de aproximadamente 60 h contínuas, a um fluxo de nêutrons de 5,5 x 1013 n cm-2 s-1. Foi produzido um total de 13,53 GBq (365,73 mCi) de iodo-125, e o único contaminante encontrado foi o radionuclídeo iodo-126. Na análise radioquímica, pelo método de cromatografia em papel ascendente, o iodo-125 em solução de NaOH apresentou percentual de iodeto acima de 98%, superior à exigência da farmacopeia americana para soluções de iodo radioativo que é de 95%. Para a análise radionuclídica foi desenvolvida uma fonte planar, a base de resina epoxídica, para a contagem do iodo-125 em detector de germânio de alta pureza. A correlação entre o iodo-125 e o iodo-126 produzido apresentou valores entre 0,5 e 0,7% após um período de decaimento de 10 d, grau de pureza suficiente para a utilização em técnicas de radioimunoensaio.
Título en inglés
Study and development of a new methodology for production of iodine-125 from xenon-124 through the method of neutron activation
Palabras clave en inglés
brachytherapy
iodine-125
iodine-126
production
xenon-124
Resumen en inglés
A new methodology of iodine-125 production was developed in this work, performing the first production of iodine-125 in Brazil. Aluminium capsules were designed, manufactured and evaluated to support condition as pressure, temperature and neutron flux in IEA-R1 Nuclear Reactor without releasing radioactive material into reactor pool. It was designed, developed and manufactured systems to load, unload and recover gases to manipulate the xenon gas and the iodine. A new method of capsule rinsing was developed, to dissolve the iodine-125 adsorbed in the walls, using immersion in ultrasonic bath. Three capsules were irradiated in IEA-R1 Nuclear Reactor for approximately 60 h continuous, at a neutron flux of 5.5 x 1013 n cm-2 s-1. It was produced a total of 13.53 GBq (365.73 mCi) of iodine-125 and the radionuclide iodine-126 was the only contaminant found. In radiochemical analysis, by ascending paper chromatography method, the iodine-125 in NaOH solution presented a percentage over 98%, higher than American pharmacopeia requirements for iodine radioactive solutions which is 95%. A planar source was developed, based on epoxy resin, to iodine-125 radionuclidic analysis in high purity germanium detector. The correlation between iodine-125 and iodine-126 produced showed values between 0.5 and 0.7% after a 10 d decay period, a purity grade enough to apply in radioimmunoassay techniques.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
2015CostaEstudo.pdf (18.97 Mbytes)
Fecha de Publicación
2015-10-28
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.