• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.85.2016.tde-11032016-093447
Document
Auteur
Nom complet
Felipe Massicano
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Jackowski, Marcel Parolin (Président)
Fernandes, Marco Antonio Rodrigues
Patrão, Diogo Ferreira da Costa
Siqueira, Paulo de Tarso Dalledone
Ximenes, Edmir
Titre en portugais
Modelagem de um sistema de planejamento em radioterapia e medicina nuclear com o uso do código MCNP6
Mots-clés en portugais
MCNP
medicina nuclear
radioterapia
sistema de planejamento dosimétrico
Resumé en portugais
O tratamento de câncer possui diversas modalidades. Uma delas é a utilização de fontes de radiação como principal protagonista do tratamento. A radioterapia e a medicina nuclear são exemplos desse tipo de tratamento. Por utilizarem a radiação ionizante como principal ferramenta para a terapia, há a necessidade de se efetuar diversas simulações do tratamento a fim de maximizar a dose nos tecidos tumorais sem ultrapassar os limites de dose nos tecidos sadios circunvizinhos. Os sistemas utilizados na simulação desses tipos de terapia recebem o nome de Sistemas de Planejamento Dosimétrico. A medicina nuclear e a radioterapia possuem seus próprios sistemas de planejamento dosimétricos devido a grande diversidade das informações necessárias às suas simulações. Os sistemas de planejamento em radioterapia são mais consolidados do que os de medicina nuclear e por tal motivo um sistema que aborde tanto os casos de radioterapia como de medicina nuclear contribuiria para significativos avanços na área de medicina nuclear. Dessa forma, o objetivo do trabalho foi modelar um Sistema de Planejamento Dosimétrico com o uso do código de Monte Carlo MCNP6 Monte Carlo N-Particle Transport Code que permitisse incorporar os casos de radioterapia e medicina nuclear e que fosse extensível a novos tipos de tratamentos. A modelagem desse sistema resultou na construção de um Framework, orientado a objetos, nomeado IBMC o qual auxilia no desenvolvimento de sistemas de planejamento que necessitam interpretar grandes quantidades de informações com o objetivo de escrever o arquivo base do MCNP6. O IBMC permitiu desenvolver de maneira rápida e prática sistemas de planejamento para radioterapia e medicina nuclear e os resultados foram validados com sistemas já consolidados. Ele também mostrou alto potencial para desenvolver sistemas de planejamento de novos tipos de tratamentos que utilizam a radiação ionizante.
Titre en anglais
Modeling of a planning system in Radiotherapy and Nuclear Medicine using the MCNP6 code
Mots-clés en anglais
MCNP
nuclear medicine
radiotherapy
treatment planning systems
Resumé en anglais
Cancer therapy has many branches and one of them is the use of radiation sources as treatment leading method. Radiotherapy and nuclear medicine are examples of these treatment types. For using the ionization radiation as main tool for the therapy, there is the need of crafting many treatment simulation in order to maximum the tumoral tissue dose without throught the dose limit in health tissue surrounding. Treatment planning systems (TPS) are systems which have the purpose of simulating these therapy types. Nuclear medicine and radiotherapy have many distinct features linked to the therapy mode and consequently they have different TPS destined for each. The radiotherapy TPS is more developed than the nuclear medicine TPS and by that reason the development of a TPS that was similar to the radiotherapy TPS, but enough generic for include other therapy types, it will contribute with significant advances in nuclear medicine and in others therapy types with radiation. Based on this, the goal of work was to model a TPS that utilizes the Monte Carlo N-Particle Transport code (MCNP6) in order to simulate radiotherapy therapy, nuclear medicine therapy and with potential for simulating other therapy types too. The result of this work was the creation of a Framework in Java language, objectoriented, named IBMC which will assist in the development of new TPS with MCNP6 code. The IBMC allowed to develop rapidly and easily TPS for radiotherapy and nuclear medicine and the results were validated with systems already consolidated. The IBMC showed high potential for developing TPS by new therapy types.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-03-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.