• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2008.tde-21092009-102313
Documento
Autor
Nombre completo
Marcello Magri Amaral
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Tarelho, Luiz Vicente Gomes (Presidente)
Rodrigues, Nicolau Andre Silveira
Samad, Ricardo Elgul
Título en portugués
Desenvolvimento de espectroscopia de plasma induzido por laser para aplicações em análise de patrimônio cultural: estudo de moedas de Um Cruzeiro de 1945 e Mil Réis de 1939
Palabras clave en portugués
Espectroscopia de plasma induzido por laser
LIBS
Plasma
Resumen en portugués
Neste trabalho foi desenvolvida a t¶ecnica de Espectroscopia de Plasma Induzido por Laser aplicada µa an¶alise de patrim^onio hist¶orico atrav¶es do estudo das moedas de Um Cruzeiro de 1945 e Mil R¶eis de 1939, utilizando um laser de Nd:YAG operando em modo de chaveamento Q. Foram determinadas as melhores condi»c~oes de energia do pulso laser e tempos de atraso entre o pulso e a aquisi»c~ao dos espectros e de integra»c~ao do sinal espectrosc¶opico para aplica»c~ao da t¶ecnica em patrim^onio hist¶orico. Para garantir a reprodutibilidade da t¶ecnica, a temperatura de excita»c~ao eletr^onica, a temperatura de ioniza»c~ao e a densidade eletr^onica do plasma foram determinadas. O dano causado µas moedas foi avaliado utilizando a t¶ecnica de Tomogra¯a por Coer^encia ¶ Optica. Utilizando o m¶etodo livre de calibra»c~ao, as concentra»c~oes elementares foram determinadas, por¶em a concentra»c~ao determinada para o Alum¶³nio, presente no material de forja, estava abaixo de seu valor nominal e do valor determinado atrav¶es da t¶ecnica de An¶alise por Ativa»c~ao Neutr^onica. Uma investiga»c~ao da fra»c~ao de ioniza»c~ao revelou que a fra»c~ao de ioniza»c~ao presente no plasma estava acima do valor esperado por ioniza»c~ao t¶ermica para as temperaturas atingidas, indicando a presen»ca de processos de ioniza»c~ao n~ao t¶ermicos, que in°uenciavam nas medidas do Alum¶³nio. Foi realizada uma corre»c~ao na concentra»c~ao do elemento, utilizando a fra»c~ao de ioniza»c~ao devido aos processos de ioniza»c~ao n~ao t¶ermicos, e os novos valores de concentra»c~ao determinados obtiveram uma grande concord^ancia com os valores nominal e determinados por An¶alise por Ativa»c~ao Neutr^onica. ii
Título en inglés
DEVELOPMENT OF LASER INDUCED BREAKDOWN SPECTROSCOPY OF ONE "CRUZEIRO" FROM 1945 AND THOUSAND "RE¶IS" FROM 1939 FOR APPLICATIONS ON CULTURAL HERITAGE ANALYSIS: STUDY OF COINS
Palabras clave en inglés
Espectroscopia de plasma induzido por laser
LIBS
Plasma
Resumen en inglés
In this work, the technique of laser induced breakdown spectroscopy was developed for application in cultural heritage analysis in order to study coins of one \Cruzeiro" from 1945 and a thousand \R¶eis" from 1939, using a Nd:YAG laser operating in Q-switched mode. It had been determined the best conditions of laser and detection features such as pulse energy, delay time between the pulse and the acquisition of spectra and integration time of the spectroscopic signal for the technique applied to cultural heritage. The electronic excitation temperature, the ionization temperature and the electronic density of the plasma had been determined in order to assure the technique reproductivity. The actual damage to the coins was evaluated using the technique of Optical Coherence Tomography. Using the calibration free method, elemental composition had been determined, however the concentration for Aluminum, forge material element , was below of its nominal value and the Neutron Activation Analysis value. An investigation of the ionization fraction disclosed that the ionization fraction of present ionization in the plasma was above of the expected value for thermal ionization at measured temperatures, indicating the presence of non thermal ionization processes, in°uencing the values for Aluminum concentration. A correction in the ionic concentration of the element was performed using the ionization fraction for non thermal processes and the new concentration values had an agreement with the nominal values and the ones determined by Neutron Activation Analysis. i
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-09-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.