Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2009.tde-22092011-092833
Documento
Autor
Nombre completo
Felipe Guimarães Albero
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Zezell, Denise Maria (Presidente)
Martinho, Herculano da Silva
Parise Junior, Orlando
Título en portugués
Diagnóstico de lesões da tireóide pela espectroscopia de absorção no infravermelho por transformada de Fourier-FTIR
Palabras clave en portugués
biópsia óptica
câncer de tireóide
espectroscopia FTIR
Resumen en portugués
Os nódulos de tireóide constituem patologia comum, com uma incidência entre 4- 7% na população brasileira. Embora a punção aspirativa por agulha fina (PAAF) seja um método com boa sensibilidade, a discriminação entre lesões benignas e neoplasias malignas não é possível em todos os casos, permitindo a incidência de diagnósticos falsos-positivos, o que conduz a tireoideotectomia pelo risco de carcinoma. O escopo deste estudo foi verificar se a espectroscopia de absorção no infravermelho por transformada de Fourier (FTIR) pode contribuir no diagnóstico diferencial entre neoplasias malignas e benignas de tecidos e aspirados. Amostras de PAAF, homogenatos e tecidos de nódulos de tireóide com o diagnóstico histopatológico foram obtidos e preparados para análise espectroscópica por FTIR. As punções e homogenatos foram medidas por -FTIR (entre 950 1750 cm-1, com resolução de 4 cm-1 e 120 varreduras). As amostras de tecido foram analisadas diretamente pela técnica de ATR-FTIR, com resolução de 2 cm-1, 60 varreduras, região entre 950 1750 cm-1.. Todos os espectros foram corrigidos pela linha base e normalizados pela área sob a banda das amidas (1550-1640 cm-1) de modo a minimizar as variações de homogeneidade das amostras. Os espectros foram então convertidos em segundas derivadas usando-se o filtro de Savitzk-Golay com 13 pontos na janela. A variância de Ward e distância euclidiana foram usadas para se processar a análise de clusters. As amostras de PAAF revelaram um complexo padrão espectral. Todas as amostras mostraram alguns aglomerados de células ou grande concentração de hormônios, tendo representação em algumas bandas em 1545 e 1655 cm-1. Foram também encontradas bandas em torno de 1409, 1412, 1414, 1578 and 1579 cm-1, indicando a possível presença de açúcares, DNA e ácido cítrico de produtos metabólitos. Neste estudo, foi obtida uma excelente separação entre bócio adenomatoso e neoplasias malignas para as amostras de tecido, com 100% de sensibilidade em determinado cluster, mas 67% no geral e 50% de especificidade. Nos homogenatos e aspirados este valor foi menor (76,2% de sensibilidade e 52,6% de especificidade) porque incluiu outros tipos de lesões. Para uma maior diferenciação das amostras de PAAF de padrão folicular, um maior número de amostras se faz necessário. Os resultados deste estudo sugerem que a espectroscopia FTIR pode ser útil na diferenciação de carcinomas da tiróide em amostras de tecidos.
Título en inglés
Thyroid lesions diagnosis by fourier transformed infrared absorption spectroscopy (FTIR)
Palabras clave en inglés
FTIR spectroscopy
thyroid cancer
Resumen en inglés
Thyroid nodules are a common disorder, with 4-7% of incidence in the Brazilian population. Although the fine needle aspiration (FNA) is an accurate method for thyroid tumors diagnosis, the discrimination between benign and malignant neoplasm is currently not possible in some cases with high incidence of false negative diagnosis, leading to a surgical intervention due to the risk of carcinomas. The aim of this study was to verify if the Fourier Transform infrared spectroscopy (FTIR) can contribute to the diagnosis of thyroid carcinomas and goiters, using samples of tissue and aspirates. Samples of FNA, homogenates and tissues of thyroid nodules with histopathological diagnosis were obtained and prepared for FTIR spectroscopy analysis. The FNA and homogenates samples were measured by -FTIR (between 950 1750 cm-1), at a nominal resolution of 4 cm-1 and 120 scans). Tissue samples were analized directly by ATR-FTIR technique, at a resolution 2 cm-1, with 60 scans in the same region. All spectra were corrected by the baseline and normalized by amides area (1550-1640 cm-1) in order to minimize variations of sample homogeneity. Then, spectra were converted into second derivatives using the Savitzk-Golay algorithm with a 13 points window. The Ward's minimum variance algorithm and Euclidean distances among the points were used for cluster analysis. Some FNA samples showed complex spectral pattern. All samples showed some cell pellets and large amount of hormone, represented by the bands of 1545 and 1655 cm-1. Bands in 1409, 1412, 1414, 1578 and 1579 cm-1 were also found, indicating possible presence of sugar, DNA, citric acid or metabolic products. In this study, it was obtained an excellent separation between goiter and malign lesion for the samples of tissues, with 100% of specificity in specific cluster and 67% sensibility and 50 of specificity. In homogenate and FNA samples this sensibility and specificity were lower, because among these samples, it were included many types of thyroid lesions. To obtain a more precise diagnosis for FNA of follicular thyroid the sample size should be increased. The results of this study suggest that FTIR spectroscopy may be useful for discriminate thyroid carcinomas from goiters in tissue samples.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-10-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.