Doctoral Thesis
DOI
https://doi.org/10.11606/T.9.1999.tde-05102011-150147
Document
Author
Full name
Célia Hitomi Yamamoto
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1999
Supervisor
Committee
Pinto, Terezinha de Jesus Andreoli (President)
Freitas, Osvaldo de
Kedor, Erika Rosa Maria
Magalhaes, Joao Fernandes
Marchetti, Juliana Maldonado
Title in Portuguese
Aspectos da qualidade da tetraciclina em preparações farmacêuticas sólidas. Correlação entre os métodos de dosagem por cromatografia líquida de alta eficiência e turbimético
Keywords in Portuguese
Antibióticos
Cromatografia líquida
Doseamento
Ensaio microbiológico
Estudo comparativo
Madicamento
Abstract in Portuguese
As tetraciclinas são encontradas no mercado sob várias formas farmacêuticas, sendo provenientes de diversos laboratórios farmacêuticos. Com o objetivo de avaliar a qualidade destes medicamentos, foram realizados os ensaios de dissolução in vitro e determinação quantitativa. Um total de 38 amostras de cápsulas de cloridrato de tetraciclina, fosfato de tetraciclina e cloridrato de oxitetraciclina e drágea de cloridrato de doxiciclina, englobando 12 fabricantes, foram analisadas. A dissolução do princípio ativo foi determinada para todas as amostras, conforme o método recomendado pela USP XXIII. Das amostras, duas foram reprovadas e outras quatro foram aprovadas após o reteste. A variação dos valores individuais obtidos no ensaio de dissolução para cada amostra, foi significativa, apresentando coeficiente de variação de até 14,2 %. A determinação quantitativa através do método microbiológico turbidimétrico empregando Staphylococcus aureus ATCC 29737, resultou em duas amostras de um mesmo fabricante com potência muito abaixo do limite especificado de 90 a 125 % do valor rotulado, com 55.5 e 68,7 %. Estudo comparativo desta metodologia com o método de cromatografia líquida de alta eficiência (CLAE) foi realizado. Para isto, o método da USP XXIII foi escolhida após o ensaio preliminar, seguido de determinação dos parâmetros de validação e adequação do método. O sistema cromatográfico estabelecido consistiu de coluna de fase reversa SYMMETRYTM C8 e fase móvel composta de oxalato de amônio 0,09 M, dimetilformamida e fosfato dibásico de amônio 0.18 M (64:32:4.7) com pH entre 7,6 e 7.7. Os resultados para determinação de cloridrato de tetraciclina confirmaram os valores obtidos no ensaio microbiológico, sendo reprovadas duas amostras. O teor máximo encontrado de 4-epianidrotetraciclina foi de 0,5 %, abaixo do limite de 3 % especificado na USP XXIII. Na comparação entre os dois métodos, foram observados resultados sempre superiores para o método microbiológico. A análise estatística destes resultados mostrou diferença significativa entre as médias das determinações obtidas a partir de cada método.
Title in English
Aspects of the quality of tetracycline in solid pharrnaceutical forrnulations. Correlation between HPLC and microbiological methods
Keywords in English
Antibiotics
Chromatographic analysis
Comparative study
Determination
Medicines
Microbiological assay
Abstract in English
Tetracyclines are avaiable under several pharmaceutical forms and manufactured by different laboratories. Aiming at the evalution of the quality of these medicines, assays of in vitro dissolution and quantitative determination have been performed in 38 samples of tetracycline hydrochloride and phosphate and oxytetracycline hydrochloride capsules and docycycline hydrochloride coated tablet taken from 12 manufactures. The range of dissolution of the substance was determined in all the samples, according to the method recommended by USP XXIII. On the whole, only two of samples were rejected and all the others approved without restrictions, except four of them, wich required a retest. The evaluation of the individual values obtained in the assay of dissolution in each sample was significant, with a variation coefficient of up to 14.2%. The quantitative determination through the turbidimetric microbiological method employing Staphylococcus aureus ATCC 29737, resulted in two samples of tetracycline hydrochloride from the same manufatures with potency of 55.5 % and 68.7 % below the specified limit from 90 % to 125 % the labeled value. A comparative study of this method and the HPLC one was then performed. The USP XXIII method was chosen after a preliminary assay, followed by the determination of its validation parameters and system suitability. The established chromatographic method employed reversed phase column SYMMETRYTM C8 (octylsilane chemically bounded to totally porous sílica particles) and mobile phase consisting of ammonium oxalate 0.09 M, dimethyformamide and dibasic ammonium phosphate 0.18 M (63.9:32:4.7) adjusted to pH 7.6-7.7. The results confirmed the values obtained in the microbiological assay. When this method (HPLC) was used for the determination of 4-epianidrotetracycline, a maximum of 0.5 % was found, below the limit of 3% specified in the USP XXIII. The comparison between both methods reavealed constant superior results in the microbiological one, and the difference between the averages of the determinations from the methods was meaningful.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-10-05
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI