Tesis Doctoral
DOI
https://doi.org/10.11606/T.9.2003.tde-28112012-132904
Documento
Autor
Nombre completo
Isarita Martins
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2003
Director
Tribunal
Rosa, Henrique Vicente Della (Presidente)
Bevilacqua, Ruy Geraldo
Loureiro, Ana Paula de Melo
Rocha, Lys Esther
Siqueira, Maria Elisa Pereira Bastos de
Título en portugués
Avaliação da exposição dos profissionais da área da saúde à ciclofosfamida
Palabras clave en portugués
Análise toxicológica
Antineoplásicos
Carcinógenos químicos (Efeitos adversos)
Ciclofosfamida
Exposição ocupacional
Toxicologia ocupacional
Resumen en portugués
Trabalhadores da área da saúde, em laboratórios, hospitais e/ou outros locais, estão potencialmente expostos a numerosos riscos ocupacionais. A ampla e crescente utilização de fármacos antineoplásicos, na quimioterapia, é considerada um importante risco químico para o pessoal envolvido no preparo e na administração destas substâncias. O manuseio destes fármacos sem cuidados pode levar a inúmeros efeitos tóxicos. Alguns destes fármacos foram classificados pela IARC como carcinógenos e provavelmente carcinógenos para humanos. Para tais fármacos é difícil atingir uma dose de não efeito observado, pois a patologia provocada por eles é considerada multifatorial. Este estudo objetivou validar método para a determinação de ciclofosfamida, um dos fármacos mais utilizados e, classificado como carcinógeno para humanos, para posterior aplicação em amostras coletadas em situação de real exposição. O analito foi identificado e quantificado por CG-EM após extração do analito em fase sólida e derivação com anidrido trifluoroacético. A ifosfamida foi utilizada como padrão interno e o fármaco foi determinado em amostras provenientes de wipe test e luvas, coletadas em quatro hospitais italianos, dentro de um intervalo de calibração de 1 a 100 ng/mL. Os intervalos de coeficiente de variação obtidos, no ensaio da precisão do método, foram entre 0,5 e 10% (intra-ensaio) e O e 19% (interensaio). Amostras contendo ciclofosfamida foram analisadas durante um mês, sem perda significativa do analito. A porcentagem de recuperação foi 98,9%. Os valores de ciclofosfamida nas 176 amostras coletadas variaram de inferior ao limite de quantificação (1,0 ng/mL) a 141.186 ng. Os resultados, bem correlacionados com aqueles relatados na literatura, sugerem que o método pode ser utilizado na identificação da ciclofosfamida em diversas superfícies e materiais e pode ser considerado ferramenta útil na monitorização da exposição ocupacional à esta substância.
Título en inglés
Evaluation of exposure to cyclophosphamide in health care workers
Palabras clave en inglés
Antineoplastic
Chemical carcinogenic
Cyclophosphamide
Occupational exposure
Occupational toxicology
Toxicological analysis
Resumen en inglés
Workers in laboratories and hospitals have potential exposure to numerous occupational hazards. The widespread use of antineoplastic drugs in chemotherapy is considered an important risk to staff involved in the preparation and administration to these drugs. Careless handling may lead toxic effects among the occupational exposure subjects. Some antineoplastic drugs were classified by IARC as carcinogenic and probably carcinogenic for humans. For carcinogenic agents the absence of a no-adverse-effect-Ievel is supposed. In this study cyclophosphamide was quantified adapting a previous analytical method by gas chromatography coupled mass spectrometry (GC-MS) after solid phase extraction and derivatization with trifluoroacetic anhydride. This drug in fact is one of the most frequently used alkylating antineoplastic agent for different types of tumors and classified as human carcinogen. The ifosfamide was used as internal standard and the drug was measured by analysis in wipe samples and gloves, collected from four different hospitals, within a range from 1 to 100 ng/mL. The values of variation coefficient varied from 0.5 to 10% (intra-assay) and from 0 to 19% (interassay). Frozen reference wipe samples containing cyclophosphamide were analysed over one month and no significant loss was observed. The range obtained for bias assay was 83-116% and the recovery was 98.9%. The cyclophosphamide was measured in 176 samples with values ranging from below limit of quantification (1.0 ng/mL) to 141186 ng. The results, well related with those reported in literature, suggest that this method can be used to identify the cyclophosphamide from surfaces and materials samples and can be considered useful in exposure assessment to this drug.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-11-28
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores