• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.98.2017.tde-10102016-065309
Documento
Autor
Nome completo
Nelson Augusto Oliveira de Aguiar
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2016
Orientador
Banca examinadora
Nicolosi, Denys Emilio Campion (Presidente)
Zanini, Angelo Sebastião
Meneghelo, Romeu Sergio
Ricchetti, Pier Marco
Título em português
Segmentação automática para classificação digital de sinais de fonocardiograma
Palavras-chave em português
Bulhas
Fonocardiograma
S1
S2
Separação
Resumo em português
Com o avanço tecnológico surgem novas ferramentas que auxiliam os médicos no diagnóstico de diversas doenças. Na área cardiovascular, após permanecer por um longo período em segundo plano, a ausculta cardíaca voltou a ser muito utilizada devido ao surgimento, no mercado, de estetoscópios digitais. Tais aparelhos contam com novos recursos tecnológicos que permitem a captação e a análise de dados de forma automática, oferecendo mais informações ao profissional da área. Levando em conta essa nova ascensão da área de Fonocardiografia,o presente trabalho se dedicou à separação das bulhas S1 e S2 por meio de ferramentas computacionais, com o propósito de auxiliar médicos não especialistas em Cardiologia a verificar a existência de possíveis anormalidades no som cardíaco. Acreditando na possibilidade de este procedimento vir a ser utilizado posteriormente para auxiliar no reconhecimento de padrões dos sons cardíacos, este trabalho se propôs a criar um algoritmo para detecção automática de anormalidades que afetam as bulhas S1 e S2. Assim, aplicou-se a técnica de Wavelet sobre uma base de dados de sons cardíacos constituída de 1209 bulhas, auditada pelo Real Hospital Português e também pelo Instituto Dante Pazzanese de Cardiologia. Os melhores resultados obtidos na separação das bulhas foram, nos sons normais, de 96,96% de acurácia para a S1 e de 97,92% para a S2. Já nos sons cardíacos com sopro, obteve-se a acurácia de 87,46% para a separação da S1 e de 89,26% para a S2. Juntos, os resultados dos sons normais e dos sons com sopro totalizaram uma acurácia de 94,02% para a separação da S1 e de 94,54% para a S2.
Título em inglês
Automatic segmentation for signal classification of digital phonocardiogram
Palavras-chave em inglês
Heart Sound
Phonocardiogram
S1
S2
Separation
Resumo em inglês
New technological tools are often created in the medical field to assist doctors in the clinical diagnosis of many diseases. After being forgotten for many years in the cardiovascular area, cardiac auscultation is now back in the spotlight, as soon as digital stethoscope became available in the market. New digital stethoscope records patient's heart sounds, which can be automatically analyzed or also sent to another device for further more detailed investigation. This feature helps physicians in the study of auscultation results. Taking into account the new rise of cardiac auscultation, the present paper attempted to provide the separation of S1 and S2 heart sounds by computer tools, in order to support non-specialist physicians in finding heart sound abnormalities. Heart sound separation can thus be employed for the creation of pattern recognition algorithms, which are able to identify abnormalities automatically. This paper proposed the development of a S1 and S2 heart sound separation algorithm by using Wavelet technique, who was applied upon a database containing 1209 individual heart sounds. The referred database was audited by Royal Portuguese Hospital and Dante Pazzanese Institute of Cardiology medical staff. The best obtained results for S1 and S2 separation in regular heart sounds were a 96.96% accuracy rate for S1 and a 97.92% accuracy rate for S2. In murmur heart sounds were obtained an 87.46% accuracy rate for S1 and an 89.26% accuracy rate for S2. Overall results achieved a 94.02% accuracy rate for S1 and a 94.54% accuracy rate for S2.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2017-01-04
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.