• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.1996.tde-30072024-120116
Documento
Autor
Nombre completo
Solange Aparecida Goularte Dombroski
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1996
Director
Tribunal
Reali, Marco Antonio Penalva (Presidente)
Bernardo, Luiz di
Mendes, Carlos Gomes da Nave
 
Título en portugués
Influência das condições de floculação na eficiência da flotação por ar dissolvido de alta taxa aplicada ao tratamento de água de abastecimento
Palabras clave en portugués
flotação por ar dissolvido
gradiente de velocidade médio de floculação
número de compartimentos de floculação
tempo de floculação
Resumen en portugués
A floculação é uma operação que influencia marcadamente na eficiência da flotação de águas de abastecimento. As condições de floculação requeridas pela flotação mostram-se diferentes daquelas geralmente assumidas pela sedimentação, já que, em cada método a remoção ocorre de maneira diferente. Aspectos fundamentais · da floculação, tais como tempo, gradiente de velocidade médio, combinações de gradiente de velocidade médio e número de compartimentos foram estudados empregando-se unidades de flotação por ar dissolvido estática e com escoamento contínuo utilizando-se água tipo I, preparada de forma a apresentar cor aparente em tomo de 100 uC e turbidez em tomo de 6 uT. Além disso, comparou-se resultados obtidos em ensaios de clarificação por flotação e por sedimentação realizados no reator estático, utilizando-se água tipo II, preparada de maneira a apresentar cor aparente em tomo de 260 uC e turbidez em tomo de 5 uT. Combinações de gradiente de velocidade médio na floculação foram estudadas utilizando-se a instalação com escoamento contínuo e água tipo II. A flotação por ar dissolvido apresentou bom desempenho para a clarificação de ambos tipos de água estudados. Os resultados com o reator estático e água tipo I comprovaram a importância da otimização de parâmetros de floculação como tempo, gradiente de velocidade médio e escalonamento do gradiente de velocidade médio. Com resultados obtidos empregando-se a instalação com escoamento contínuo e água tipo I comprovou-se que o escalonamento de gradiente de velocidade médio na floculação é mais significativo na eficiência do processo para tempos de floculação menores.
 
Título en inglés
lnfluence of flocculation conditions in high rate dissolved air flotation efficiency when applied to drinking water treatment
Palabras clave en inglés
dissolved air flotation
flocculation root mean square
flocculation time
number of flocculation chambers
Resumen en inglés
Flocculation is one of the main unit operation a:ffecting drinking water flotation efficiency. The flocculation conditions required by flotation are different from those usually required by sedimentation, since in each method the removal occurs in a different way. Some fundamental aspects of flocculation were studied, such as time, root mean square, root mean square combinations and number of flocculation chambers by using a batch flotation unit and a continuous flow flotation plant, treating type I water, prepared to present an apparent color of approximately 100 CU and turbidity of 6 NTU. Besides that, essays of clarification by flotation and by sedimentation were executed in the batch unit and were compared, using type II water, prepared to present 260 CU of apparent colar and turbidity about 5 NTU. Some combinations of the root mean square were studied using the continuous flow plant and type II water. Dissolved air flotation presented a good performance for the clarification of both types of studied water. The results obtained with the batch unit and type I water proved the importance of optimizing parameters like time, root mean square, and root mean square scaling. The results obtained with the continuous flow plant and type I water showed that scaling the root mean square is more significative for the process e:fficiency for shorter flocculation times.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-07-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores.
CeTI-SC/STI
© 2001-2024. Biblioteca Digital de Tesis y Disertaciones de la USP.