Título en portugués
Desenvolvimento de um Venturi sônico como padrão para medição de vazão..
Palabras clave en portugués
Engenharia mecânica
Gases
Resumen en portugués
Foi estudado um Venturi sônico para utilização como padrão em um laboratório de vazão de gases, cobrindo a faixa de vazão mássica entre 0,005 e 0,025 kg/s, o que levou ao dimensionamento de um Venturi com 5mm de diâmetro de garganta. Foi proposto, construído e ensaiado um tipo de Venturi não convencional, com um degrau entre a garganta cilíndrica e o divergente. Os resultados obtidos possibilitaram concluir que os valores do coeficiente de descarga não se alteram com o tamanho do degrau, o que permite, devido a excelente repetibilidade obtida, que esta configuração de Venturi possa ser normalizada e utilizada como um padrão. Por outro lado, para degraus negativos, ou seja, para diâmetros da garganta maiores que o diâmetro do divergente, o coeficiente de descarga não varia com o número de Reynolds. Isto abriu um assunto interessante de pesquisa, pois não há registros conhecidos de medidores de vazão por perda de carga com as características dos medidores sônicos e que sejam independentes do número de Reynolds, na faixa medida.
Título en inglés
Untitled in english
Palabras clave en inglés
Gases
Mechanical engineering
Resumen en inglés
Sonic nozzles have been studied, to be used as standard flowmeter, in a Gas Flow Laboratory. To fulfil needs of of the Laboratory, a 5mm throat diameter Venturi was studied, for low flowrates, between 0,005 kg/s and 0,025 kg/s. As the dimensional tolerances required by the standards are very strict for this size, it was proposed, constructed and tested a non conventional type of Venturi nozzle, with a step between the cilyndrical throat and the separable diffuser. The results showed that the discharge coefficient has not changed with the size of the step, which allows, due to the excellent repeatability, the standardization of this Venturi configuration. In conclusion, this Venturi can be used as a standard flowmeter. For negative steps, i.e., for throat diameter greater than diffuser diameter, the discharge coefficient has not changed with Reynolds number (between 0,8X10 and 2,5X10). This has open an interesting subject to research, because there is no reports of sonic pressure drop flowmeters with this characteristics, at such low Reynolds numbers.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-06-28
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.